The bi-weekly Global ICS Anomaly Hunter scan executed at 22:01 UTC on October 8, 2026 flagged a score-7 anomaly: an Nginx web server answering on TCP port 20000 (DNP3 industrial protocol) in Los Angeles, US, with exposed PSI (pounds per square inch) control metrics.
This is the fourth consecutive scan to detect the nginx-on-DNP3 pattern — a persistent anomaly that has now appeared in scans on August 6, August 27, August 31, October 1, and October 8, 2026.
TCP port 20000 is the standard port for DNP3 (Distributed Network Protocol), widely used in North American water treatment, electric power, and pipeline SCADA systems. Finding an Nginx web server on this port indicates one of several possibilities:
The presence of PSI (pressure) control metrics suggests this is not a honeypot or scan artifact — it is a live service responding with real industrial telemetry data on the public internet.
This is the fourth consecutive bi-weekly scan to flag nginx-on-DNP3 anomalies. The persistence of this pattern across multiple scanning cycles indicates it is not transient — it represents a standing exposure.
The Global ICS Anomaly Hunter executed 4 queries across 36 results, flagging 18 anomalies total. The scoring distribution:
| Score | Count | Assessment |
|---|---|---|
| 7 | 1 | High — Immediate attention required |
| 5 | 2 | Elevated — IIS on industrial port 102 (Iran) |
| 4 | 14 | Moderate — Notable patterns |
| 3 | 1 | Low — Minor anomalies |
| 0 | 36 | Normal — No unusual indicators |
Two additional score-5 anomalies were detected in the unauth_ics query (Iran, port 102 / Siemens S7):
The companion Future Products scanner executed 8 vendor-targeted queries across Wind/Gen, Water/Flow, and Smart Grid sectors. Results:
| Sector | Queries | Targets Found | Notes |
|---|---|---|---|
| Wind/Gen | 3 | 0 | Vestas, Siemens Gamesa, GE Wind — no results |
| Water/Flow | 3 | 0 | SCADAPack, Motorola MOSCAD, Xylem — no results |
| Smart Grid | 2 | 6 | Moxa: 6 targets on port 102 |
Six Moxa Smart Grid devices were discovered on port 102 (Siemens S7 protocol), representing potential future article candidates for the Smart Grid exposure landscape.
Data collected via the Shodan Developer API with 4 targeted queries:
port:502 country:CN — Modbus exposure in China (20 results)port:102 country:IR — Siemens S7 exposure in Iran (20 results)port:2404 country:RU — IEC-104 exposure in Russia (20 results)port:20000 country:US — DNP3 exposure in the US (20 results)All IP addresses and organization names are defanged per our non-attribution policy. Scoring uses a multi-factor weirdness model considering protocol-product mismatch, cloud-hosting anomalies, exposed control metrics, and geographic-political context.
Disclaimer: We do not attribute vulnerabilities to specific targets, governments, or corporations. All findings are published at the protocol, sector, or country level only. IP addresses and organization names are defanged.